DLD-50G 2D Single-line LiDAR (Diffuse-remission Measuring Type)

2D single-line laser scanner measuring diffuse-remission distance off natural surfaces, no reflector needed.

Technical Specifications

Product CategoryLaser scanning lidar
Scan Type2D single-line
Measuring TypeDiffuse-remission measuring type (no reflector required)

Overview

DLD-50G belongs to DAIDISIKE's laser scanning lidar range and is classified as a 2D single-line, diffuse-remission measuring type scanner. It is intended for integrators who need contour or profile data from objects, materials, or moving equipment that cannot practically carry a reflective target.

Unlike single-point distance sensors, it rotates a single scan plane to build a distance profile across a cross-section on every revolution. Its diffuse-remission design reads distance directly from the natural, non-cooperative surface of the target, so no reflector, reflective tape, or corner-cube target needs to be installed.

DLD-50G Procurement Fields to Confirm

A DLD-50G-specific parameter document has not been established from the material used for this page. The DLD-50D manual is not a DLD-50G datasheet, and a similar housing or a '50' model code does not establish shared performance.

Required fieldCurrent DLD-50G statusProvide or request before selection
Range and accuracyNot confirmed for this modelRequired nearest/farthest positions, allowed error and actual target sample; request the rated reflectivity conditions
Interface and protocolNot confirmed for this modelController input and host-software requirements; request interface, protocol, connector and pinout
SupplyVoltage and power/current not confirmedInstallation supply and cable run; request the model-specific electrical specification
IP and environmentIP rating and temperature limits not confirmedIndoor/outdoor exposure, dust, water, sunlight and temperature; request the applicable rating
Mechanical and delivery scopeOrdered drawing and accessories need confirmationMounting space, cable/connector requirements, quantity and destination; ask the quotation to list included items and lead time

Do not finalize a bracket, electrical connection or guaranteed range on the basis of the DLD-50D or DLD50T8 documents. Compare the separate DLD-50D and DLD50T8N/P pages only as other procurement options.

Request DLD-50G-specific technical confirmation with the target, distance span and controller requirements.

Features & Benefits

No Reflector Required

As a diffuse-remission measuring type, the DLD-50G reads the return signal directly from the object's own surface reflectivity. This eliminates the installation and upkeep of reflector plates or cooperative targets on the target object.

Full Cross-Section Profile per Revolution

A single scanning line outputs the distance distribution across an entire plane on each rotation. This delivers far more scene information than a single-point distance sensor capturing the same instant.

Works on Non-Cooperative Objects

The reflector-free operating principle makes the DLD-50G applicable to bulk materials, moving vehicles, or irregular objects where mounting a cooperative target is impractical or impossible.

Compact Rotating-Head Design

Product photos show a compact enclosure with a rotating scan head assembly and a status indicator strip, consistent with a self-contained rotating 2D scanning lidar unit.

Applications

Contour Measurement Without Reflective Targets — Where objects cannot carry a reflector, the DLD-50G measures the object's own surface directly, since no cooperative target is required.
Distance Profiling of Bulk Materials — The diffuse-remission measuring principle makes it suitable for profiling natural surfaces such as bulk material piles that are not reflective targets.
Position/Contour Sensing on Moving Equipment — For moving objects that cannot mount a reflector, the reflector-free operation allows contour or position sensing directly off the equipment surface.
2D Scene Profiling Beyond Single-Point Distance — Where a single distance reading is not enough, the single-line scan outputs a full cross-sectional distance profile on every rotation.

Models & Ordering Information

DLD-50G Series

DLD-50G
Currently the only model listed for this series; sub-variants for output type, range, and supply voltage are not documented yet.

PDF & 3D CAD Downloads

Browse all downloads

DLD-50D User Manual - Shared 50 m LiDAR Reference

English reference edition · 24.3 MB

22 pages. The manual names DLD-50DH/DC/DP variants and is shared here as a reference for the listed 50 m products; it does not establish identical specifications for DLD-50G or DLD50T8N/P. Confirm the ordered interface, wiring and firmware before use. Some dimension-drawing labels remain in Chinese.

Confirm the document and CAD file match the exact ordered version before installation or mechanical design. Contact us if your model is not listed.

How to Select

  1. DLD-50G is currently the only model listed for this series; no sub-variants for output type, range, or supply voltage are documented yet.
  2. The relationship between DLD-50G and DLD-50D (sister model vs. different-generation product) has not been confirmed by the factory, so no comparison is published between them.

📘 Need the full method? How to Choose a 2D LiDAR Scanner

When NOT to specify the DLD-50G — and what to use instead

Using DLD-50G as the protective sensor in a machine safety function to stop machinery and protect a person

Why not: No safety rating or certified OSSD personnel-protection function is established by the DLD-50G material reviewed for this page. Only the product classification and measuring principle are currently confirmed; do not use this measurement LiDAR as the sole protective device in a safety function.

Use instead: The DAIDISIKE ST27 Series Safety Laser Scanner — Type 3 / SIL 2 / Cat. 3 PL d, OSSD outputs, 3 m or 5 m protective field at 1.8% remission.

A project that requires a committed detection range or ranging accuracy

Why not: We do not publish a detection range, ranging accuracy or angular resolution for DLD-50G, because the factory has not confirmed them. We will not quote a number we cannot stand behind.

Use instead: Ask us for the missing figures before specifying this model, or compare models with published figures: DLD-50D (50 m @90% remission, ±20 mm repeatability and ±30 mm detection accuracy) or DLD-100D (100 m @90% reflectivity, ±20 mm ranging accuracy). These are separate devices, not substitutes without evaluation.

You need a specific output or interface type to integrate with a given controller

Why not: The output interface and communication protocol of DLD-50G are not documented in any source we hold.

Use instead: Confirm the interface with us before specifying, or choose a model with a published interface such as the Ethernet 100BASE-TX documented for DLD-50D and DLD-100D.

Outdoor, washdown or dusty deployment where an ingress rating is required

Why not: No IP rating is published for DLD-50G.

Use instead: Confirm the ingress rating with us before outdoor or washdown deployment, or use a model with a published IP67 rating such as DLD-50D or DLD-100D.

Deployment in an occupied space where the laser must be confirmed eye-safe under a recognised class

Why not: The laser wavelength, optical power and safety class of DLD-50G are not published.

Use instead: Request laser-class confirmation from us before deploying near people, or use a model with a published Class 1 905 nm source such as DLD-50D or DLD-100D.

Specifications we do not publish yet

We only publish a figure once we are confident it is true. The items below are still being validated through further testing and real-world customer feedback, so for now we would rather leave them open than guess. If one of them matters to your design, ask us for the latest validated status.

  • Detection range / maximum distance.
  • Ranging and detection accuracy.
  • Scan angle (field of view).
  • Scan frequency.
  • Angular resolution.
  • Output interface and communication protocol.
  • Operating voltage and power consumption.
  • Laser wavelength, optical power and safety class.
  • Ingress protection (IP) rating.
  • Operating temperature range, dimensions, weight and enclosure material.
  • Certification status, issuing body and exact-model scope; request applicable evidence before committing a conformity requirement.

Frequently Asked Questions

What does "diffuse-remission measuring type" mean for the DLD-50G?
It means the sensor is designed to measure distance by reading the diffuse reflection (remission) from the natural surface of the target object itself, rather than requiring a reflector, reflective tape, or corner-cube target mounted on the object.
Does the DLD-50G require a reflector or cooperative target to operate?
No. As a diffuse-remission measuring type 2D lidar, it is designed to work off non-cooperative, natural surfaces without an installed reflector.
Is the DLD-50G a single-point sensor or a scanning sensor?
It is a 2D single-line scanning lidar. It rotates a single scan plane to output a distance profile across a cross-section, rather than a single fixed-point distance reading.
What certifications does the DLD-50G carry?
Request the certificate or declaration applicable to the exact DLD-50G configuration. This page does not publish a certificate number, issuing body or verified model-specific scope.

Related Categories and Example Products

Explore other functions that may be needed in a machine or line. The products below are category examples, not pre-validated electrical or safety combinations. Confirm each interface and application separately: Relay & Timer Modules · Safety Light Curtains · Proximity Sensors

Related Products in LiDAR Scanners

Browse all LiDAR Scanners →

Get a QuoteWhatsApp