🔍 Click to enlarge · 1/5Technical Specifications
| Measuring principle | Phase-based laser distance measurement |
|---|---|
| Measuring ranges | 0.1-1 / 0.1-2 / 0.1-5 / 0.1-10 / 0.1-20 / 0.1-50 m, according to model |
| Resolution | 1 mm; not a repeatability specification |
| Measurement error | +(2 mm + d × 0.0001) as printed; d is measured distance. Confirm tolerance notation and test conditions. |
| Laser | Red semiconductor laser, Class II, <1 mW; wavelength printed as 655 +10 nm. Confirm tolerance notation. |
| Supply voltage | 12-24 V DC; table +10% and circuit ±10% differ. Confirm ordered-unit tolerance; ripple P-P 10%. |
| Current consumption | ≤50 mA at 24 V |
| Control output | NPN or PNP according to model; max. 50 mA; applied voltage <30 V DC; residual voltage <1.5 V; leakage <0.1 mA |
| Output action / protection | Normally open / normally closed selectable; self-recovering short-circuit protection |
| Analog voltage option | 0-5 V; alarm 5.2 V; output impedance 100 Ω |
| Analog current option | 4-20 mA; alarm 0 mA; source states output impedance max. 300 Ω |
| Communication | RS485; protocol and register map to confirm for the ordered version |
| Response time | 50-200 ms |
| External input | Pink wire; source table NPN wording differs from the PNP circuit. Confirm version-specific wiring. |
| Protection / material | IP67 / aluminum |
| Operating / storage temperature | -10 to +45°C, no condensation or frost / -20 to +60°C |
| Operating humidity / altitude | 35-85% RH / ≤2,000 m |
| Ambient illumination | Incandescent lamp: ≤3,000 lux at the receiving surface |
| Cable / mass | 2 m, eight-core composite cable / approximately 150 g |
| Dimensions | See original mm drawing in the English datasheet; confirm clearances and the ordered connector. |
Overview
DDK-F uses phase-based laser distance measurement. Six range options cover 0.1-1 m, 0.1-2 m, 0.1-5 m, 0.1-10 m, 0.1-20 m and 0.1-50 m. Each range has a separately listed NPN or PNP switching-output model, with RS485 and analog current or voltage options for industrial measurement and control.
A local display and M, SET, UP and DOWN keys support configuration without a PC. The supplied sheet specifies 1 mm resolution, a 50-200 ms response time, an aluminum housing and IP67 protection. Select the exact range, switching-output version and analog option before ordering; test the actual target and installation conditions.
Features & Benefits
Six Measuring Ranges
Select a maximum distance of 1, 2, 5, 10, 20 or 50 m. All six published ranges start at 0.1 m; choose using actual nearest and farthest target positions.
NPN or PNP Output Models
Each range has separate NM NPN and PM PNP switching-output codes. Select the output to match the controller input; field switching between NPN and PNP is not documented.
RS485 and Analog Options
The model table lists switching output, analog output and RS485. Confirm whether the ordered analog option is 0-5 V or 4-20 mA; simultaneous voltage and current output is not established.
Local Display and Setup
Configure at the device with M, SET, UP and DOWN. English and Chinese menus, baud-rate selection and station-address selection are described in the supplied sheet.
Metal Housing and IP67 Protection
The aluminum housing is listed at approximately 150 g with a 2 m eight-core composite cable. Check the dimension drawing and final connection arrangement before installation.
Output Circuit References
The English datasheet includes separate NPN and PNP circuits and the original dimension drawing. Confirm the external-input connection and supply tolerance for the ordered version.
Applications
Models & Ordering Information
0.1-1 m
0.1-2 m
0.1-5 m
0.1-10 m
0.1-20 m
0.1-50 m
PDF & 3D CAD Downloads
Browse all downloadsDDK-F Laser Distance Sensor - English Datasheet
2 pages: twelve models, six ranges up to 50 m, technical data, original mm drawing and translated NPN/PNP circuit labels. Source tolerance notation and external-input differences are noted; confirm the ordered configuration.
Confirm the document and CAD file match the exact ordered version before installation or mechanical design. Contact us if your model is not listed.
How to Select
- Select the measuring range using actual nearest and farthest target positions; the published minimum is 0.1 m.
- Choose the exact NM NPN or PM PNP output model to match the controller input.
- Confirm the 0-5 V or 4-20 mA analog option, receiving-circuit requirements and RS485 protocol before ordering.
- Evaluate accuracy and response time separately from the 1 mm reading resolution. Test representative target colors and reflectance.
- Use the dimension drawing and circuit for the ordered version. Verify supply tolerance and external-input connection because the source has differing statements.
- Keep temperature, illumination, humidity and altitude within the published limits. IP67 alone does not establish fog/snow performance.
- For distances above 50 m, request a separately specified sensor with the required range.
- Observe Class II laser precautions. Personnel protection requires an appropriate protective device and validated safety control system.
📘 Need the full method? NPN vs PNP Sensor Outputs Explained
When NOT to specify the DDK-F — and what to use instead
Target distance exceeds 50 m.
Why not: The designated series sheet specifies a maximum range of 0.1-50 m.
Use instead: a separately documented sensor with the required range
The target is closer than 0.1 m.
Why not: All six published ranges start at 0.1 m.
Use instead: a short-range sensor rated for the actual minimum distance
The task requires micron-level displacement or guaranteed 1 mm accuracy.
Why not: The 1 mm figure is resolution; it is not a guaranteed accuracy or repeatability figure.
Use instead: a displacement sensor selected by verified measurement performance and target conditions
The sensor would be the sole protective device for people.
Why not: The sheet describes ordinary measurement outputs without documented functional-safety performance.
Use instead: a protective device and validated safety control system appropriate to the machine risk assessment
Specifications we do not publish yet
We only publish a figure once we are confident it is true. The items below are still being validated through further testing and real-world customer feedback, so for now we would rather leave them open than guess. If one of them matters to your design, ask us for the latest validated status.
- Confirm the intended tolerance notation for the printed error and wavelength figures.
- Confirm supply tolerance: table +10% versus circuit ±10%.
- Confirm the external-input connection for the ordered version: NPN wording and PNP circuit differ.
- Confirm analog configuration, RS485 protocol, register map and supported baud rates.
- Repeatability, detailed target test conditions and separate fog/snow performance are not specified.
- Request applicable certificates and the final order drawing; the translated datasheet is not a certification document.
Frequently Asked Questions
What is the maximum measuring range of the DDK-F laser distance sensor?
What do the resolution and error specifications mean?
What measuring principle does DDK-F use?
What outputs does DDK-F provide?
What laser class is specified for DDK-F?
What power supply does DDK-F require?
What are the environmental limits?
Are the NPN and PNP versions interchangeable?