DDK-F Long-range Laser Distance Sensor

Phase-based laser distance measurement, six ranges up to 50 m, NPN or PNP output, RS485 and analog options.

Technical Specifications

Measuring principlePhase-based laser distance measurement
Measuring ranges0.1-1 / 0.1-2 / 0.1-5 / 0.1-10 / 0.1-20 / 0.1-50 m, according to model
Resolution1 mm; not a repeatability specification
Measurement error+(2 mm + d × 0.0001) as printed; d is measured distance. Confirm tolerance notation and test conditions.
LaserRed semiconductor laser, Class II, <1 mW; wavelength printed as 655 +10 nm. Confirm tolerance notation.
Supply voltage12-24 V DC; table +10% and circuit ±10% differ. Confirm ordered-unit tolerance; ripple P-P 10%.
Current consumption≤50 mA at 24 V
Control outputNPN or PNP according to model; max. 50 mA; applied voltage <30 V DC; residual voltage <1.5 V; leakage <0.1 mA
Output action / protectionNormally open / normally closed selectable; self-recovering short-circuit protection
Analog voltage option0-5 V; alarm 5.2 V; output impedance 100 Ω
Analog current option4-20 mA; alarm 0 mA; source states output impedance max. 300 Ω
CommunicationRS485; protocol and register map to confirm for the ordered version
Response time50-200 ms
External inputPink wire; source table NPN wording differs from the PNP circuit. Confirm version-specific wiring.
Protection / materialIP67 / aluminum
Operating / storage temperature-10 to +45°C, no condensation or frost / -20 to +60°C
Operating humidity / altitude35-85% RH / ≤2,000 m
Ambient illuminationIncandescent lamp: ≤3,000 lux at the receiving surface
Cable / mass2 m, eight-core composite cable / approximately 150 g
DimensionsSee original mm drawing in the English datasheet; confirm clearances and the ordered connector.

Overview

DDK-F uses phase-based laser distance measurement. Six range options cover 0.1-1 m, 0.1-2 m, 0.1-5 m, 0.1-10 m, 0.1-20 m and 0.1-50 m. Each range has a separately listed NPN or PNP switching-output model, with RS485 and analog current or voltage options for industrial measurement and control.

A local display and M, SET, UP and DOWN keys support configuration without a PC. The supplied sheet specifies 1 mm resolution, a 50-200 ms response time, an aluminum housing and IP67 protection. Select the exact range, switching-output version and analog option before ordering; test the actual target and installation conditions.

Features & Benefits

Six Measuring Ranges

Select a maximum distance of 1, 2, 5, 10, 20 or 50 m. All six published ranges start at 0.1 m; choose using actual nearest and farthest target positions.

NPN or PNP Output Models

Each range has separate NM NPN and PM PNP switching-output codes. Select the output to match the controller input; field switching between NPN and PNP is not documented.

RS485 and Analog Options

The model table lists switching output, analog output and RS485. Confirm whether the ordered analog option is 0-5 V or 4-20 mA; simultaneous voltage and current output is not established.

Local Display and Setup

Configure at the device with M, SET, UP and DOWN. English and Chinese menus, baud-rate selection and station-address selection are described in the supplied sheet.

Metal Housing and IP67 Protection

The aluminum housing is listed at approximately 150 g with a 2 m eight-core composite cable. Check the dimension drawing and final connection arrangement before installation.

Output Circuit References

The English datasheet includes separate NPN and PNP circuits and the original dimension drawing. Confirm the external-input connection and supply tolerance for the ordered version.

Applications

PLC Distance Monitoring — Compare the selected range, 50-200 ms response time and switching output with the PLC input and process requirements. This is an integration example, not a verified customer installation.
Material Position or Level Checks — Trial representative target surfaces over the required distance. Dark targets, strong ambient light and temperature changes can increase measurement error.
Analog Instrument Integration — Choose the current or voltage option matching the receiving instrument. Use analog ground and supply wiring from the applicable circuit.
RS485 Distance Acquisition — Use RS485 A+ and B- after confirming baud rate, addressing and the applicable protocol documentation.
Local Threshold Detection — Teach a threshold using the device controls and select normally open or normally closed action. Match the load to the rated 50 mA control output.
Machine Position Feedback — Evaluate the selected version for ordinary machine measurement. The supplied sheet does not establish a functional-safety rating or a personnel-protection function.

Models & Ordering Information

0.1-1 m

DDK-F100NM-485DDK-F100PM-485
NM: NPN output; PM: PNP output. Confirm analog option.

0.1-2 m

DDK-F200NM-485DDK-F200PM-485
NM: NPN output; PM: PNP output. Confirm analog option.

0.1-5 m

DDK-F500NM-485DDK-F500PM-485
NM: NPN output; PM: PNP output. Confirm analog option.

0.1-10 m

DDK-FM10NM-485DDK-FM10PM-485
NM: NPN output; PM: PNP output. Confirm analog option.

0.1-20 m

DDK-FM20NM-485DDK-FM20PM-485
NM: NPN output; PM: PNP output. Confirm analog option.

0.1-50 m

DDK-FM50NM-485DDK-FM50PM-485
NM: NPN output; PM: PNP output. Confirm analog option.

PDF & 3D CAD Downloads

Browse all downloads

DDK-F Laser Distance Sensor - English Datasheet

English reference translation · 1.7 MB

2 pages: twelve models, six ranges up to 50 m, technical data, original mm drawing and translated NPN/PNP circuit labels. Source tolerance notation and external-input differences are noted; confirm the ordered configuration.

Confirm the document and CAD file match the exact ordered version before installation or mechanical design. Contact us if your model is not listed.

How to Select

  1. Select the measuring range using actual nearest and farthest target positions; the published minimum is 0.1 m.
  2. Choose the exact NM NPN or PM PNP output model to match the controller input.
  3. Confirm the 0-5 V or 4-20 mA analog option, receiving-circuit requirements and RS485 protocol before ordering.
  4. Evaluate accuracy and response time separately from the 1 mm reading resolution. Test representative target colors and reflectance.
  5. Use the dimension drawing and circuit for the ordered version. Verify supply tolerance and external-input connection because the source has differing statements.
  6. Keep temperature, illumination, humidity and altitude within the published limits. IP67 alone does not establish fog/snow performance.
  7. For distances above 50 m, request a separately specified sensor with the required range.
  8. Observe Class II laser precautions. Personnel protection requires an appropriate protective device and validated safety control system.

📘 Need the full method? NPN vs PNP Sensor Outputs Explained

When NOT to specify the DDK-F — and what to use instead

Target distance exceeds 50 m.

Why not: The designated series sheet specifies a maximum range of 0.1-50 m.

Use instead: a separately documented sensor with the required range

The target is closer than 0.1 m.

Why not: All six published ranges start at 0.1 m.

Use instead: a short-range sensor rated for the actual minimum distance

The task requires micron-level displacement or guaranteed 1 mm accuracy.

Why not: The 1 mm figure is resolution; it is not a guaranteed accuracy or repeatability figure.

Use instead: a displacement sensor selected by verified measurement performance and target conditions

The sensor would be the sole protective device for people.

Why not: The sheet describes ordinary measurement outputs without documented functional-safety performance.

Use instead: a protective device and validated safety control system appropriate to the machine risk assessment

Specifications we do not publish yet

We only publish a figure once we are confident it is true. The items below are still being validated through further testing and real-world customer feedback, so for now we would rather leave them open than guess. If one of them matters to your design, ask us for the latest validated status.

  • Confirm the intended tolerance notation for the printed error and wavelength figures.
  • Confirm supply tolerance: table +10% versus circuit ±10%.
  • Confirm the external-input connection for the ordered version: NPN wording and PNP circuit differ.
  • Confirm analog configuration, RS485 protocol, register map and supported baud rates.
  • Repeatability, detailed target test conditions and separate fog/snow performance are not specified.
  • Request applicable certificates and the final order drawing; the translated datasheet is not a certification document.

Frequently Asked Questions

What is the maximum measuring range of the DDK-F laser distance sensor?
Six ranges are listed from 0.1-1 m to 0.1-50 m. The 50 m models are DDK-FM50NM-485 and DDK-FM50PM-485.
What do the resolution and error specifications mean?
Resolution is 1 mm. The error formula is printed as +(2 mm + d × 0.0001), with d denoting measured distance. Confirm the intended tolerance notation and test conditions; resolution alone does not establish accuracy or repeatability.
What measuring principle does DDK-F use?
The designated series sheet describes phase-based laser distance measurement.
What outputs does DDK-F provide?
NPN or PNP switching-output models with RS485 and analog options are listed. Confirm 0-5 V or 4-20 mA on the ordered unit; simultaneous current and voltage output is not confirmed.
What laser class is specified for DDK-F?
The sheet states a Class II red semiconductor laser below 1 mW. Follow laser precautions and avoid looking directly into the beam.
What power supply does DDK-F require?
The source lists 12-24 V DC. Its table prints +10% while the circuits print ±10%; confirm the applicable tolerance before connection.
What are the environmental limits?
IP67, -10 to +45°C operating temperature without condensation or frost, 35-85% RH and altitude up to 2,000 m are listed. Fog/snow accuracy is not specified.
Are the NPN and PNP versions interchangeable?
They are separately listed output models. Select the matching NM or PM code and its circuit; the source does not establish switching between NPN and PNP on the same unit.
Can DDK-F be used for machine distance monitoring?
Evaluate it for ordinary measurement within the selected model's rated conditions after target and controller testing. The sheet does not establish a functional-safety rating or a personnel-protection function.

Related Categories and Example Products

Explore other functions that may be needed in a machine or line. The products below are category examples, not pre-validated electrical or safety combinations. Confirm each interface and application separately: Relay & Timer Modules · Laser Displacement Sensors · LiDAR Scanners

Related Products in Laser Distance Sensors

Browse all Laser Distance Sensors →

Get a QuoteWhatsApp